Input:
0 to ±20 mA, 0 to ±10 mA, 0 to ±10 V, 0 to ±5 V,  live/dead-zero

Output:
0 to ±20 mA, 0 to ±10 mA, 0 to ±10 V, 0 to ±5 V,  live/dead-zero

Power supply:
20 to 253 V AC/DC

Features:
Pluggable screw clamp terminals, zero/span compensation,
protective separation, housing width: 12.5 mm

Input:
0 to ±20 mA, 0 to ±10 mA, 0 to ±10 V, 0 to ±5 V,  live/dead-zero

Output:
0 to ±20 mA, 0 to ±10 V

Filter function:
Cut-off frequency: 10 Hz, 1 Hz, 0.5 Hz, 0.1 Hz

Power supply:
20 to 253 V AC/DC

Features:
Pluggable screw clamp terminals, zero/span compensation, protective separation, housing width: 12.5 mm

Input:
0 to 20 mA, 0 to 10 mA, 0 to 10 V, 0 to 5 V,  live/dead-zero

Output:
0 to 20 mA, 0 to 10 mA, 0 to 10 V, 0 to 5 V,  live/dead-zero

Characteristic: inverse characteristic

Power supply:
20 to 253 V AC/DC

Features:
Pluggable screw clamp terminals, zero/span compensation,
protective separation, housing width: 12.5 mm

Input:
0 to ±20 mA, 0 to ±10 mA, 0 to ±10 V, 0 to ±5 V,  live/dead-zero

Output:
0 to ±20 mA, 0 to ±10 mA, 0 to ±10 V, 0 to ±5 V,  live/dead-zero

Power supply:
24 V DC

Features:
calibrated signal setting, zero/span compensation, protective separation, housing width: 6.2 mm

Input:
±10 V, ±5 V, ±20 mA, ±10 mA, 0 to 10 V, 0 to 5 V, 0 to 20 mA, 2 to 10 V, 1 to 5 V, 4 to 20 mA

Output:
0 to 10 V, 0 to 5 V, 0 to 20 mA, 2 to 10 V, 1 to 5 V, 4 to 20 mA

Power supply:
24 V AC/DC

Features:
Protective separation, housing width: 11.2 mm

Input:
0 to 20 mA, 4 to 20 mA, 0 to 10 V, 2 to 10 V, calibrated switchable

Output:
0 to 20 mA, 4 to 20 mA, 0 to 10 V, 2 to 10 V, calibrated switchable

Power supply:
24 V DC

Features:
Protective separation, housing width: 6.2 mm

Input:
0/4 to 20 mA, Energization of 2-wire transmitters

Output:
0/4 to 20 mA, Bidirectional HART communication

Power supply:
24 V DC

Features:
Protective separation, housing width: 6.2 mm

Input: 4 to 20 mA
Output: 4 to 20 mA

Voltage drop: Approx. 4.7 V

Features:
Protective separation, housing width: 11.2 mm

1- or 2-channel

Input: 0(4) to 20 mA
Output: 0(4) to 20 mA

Voltage drop: < 2.0 V

Features:
Pluggable screw clamp terminals, protective separation,
housing width: 12.5 mm

1- or 2-channel

Input: 0(4) to 20 mA
Output: 0(4) to 20 mA

Voltage drop: < 2.3 V

Features:
Protective separation, housing width: 6.2 mm

1- and 2-channel versions

Input: 0(4) to 20 mA
Output: 0(4) to 20 mA

Voltage drop: < 3 V

Features:
Protective separation, housing width: 11.2 mm

Input: customer-specific
Output: customer-specific

Power supply:
20 to 253 V AC/DC

Features:
Pluggable screw clamp terminals, zero/span compensation optional, protective separation, housing width: 12.5 mm

Input:
0...20 mA, 4...20 mA, 0...10 V

Output:
0...20 mA, 4...20 mA, 0...10 V

Power supply:
20 ... 253 V AC/DC

Features:
Pluggable screw clamp terminals, calibrated signal setting, protective separation, housing width: 12.5 mm

Input:
0 to 20 mA, 4 to 20 mA, 0 to 5 V, 1 to 5 V, 0 to 10 V, 2 to 10 V

Output I and II:
0 to 20 mA, 4 to 20 mA, 0 to 5 V, 1 to 5 V, 0 to 10 V, 2 to 10 V

Power supply:
24 V DC

Features:
Calibrated signal setting, protective separation, housing width: 6.2 mm

Input:
0 to 20 mA, 4 to 20 mA, 0 to 10 V

Output:
0 to 20 mA, 4 to 20 mA, 0 to 10 V

Power supply: 20 to 253 V AC/DC

Features:
Pluggable screw clamp terminals, calibrated signal setting, housing width: 12.5 mm

Input:
0 to 20 mA, 4 to 20 mA, 0 to 10 V, terminal selectable

Output:
0 to 20 mA, 4 to 20 mA, 0 to 10 V, terminal selectable

Power supply:
24 V DC

Features: solder-in module, Calibrated signal setting, 3-port isolation, flat module housing for PCB assembling

Input:
0 to 20 mA, 4 to 20 mA, 0 to 10 V, 2 to 10 V, calibrated switchable

Output:
0 to 20 mA, 4 to 20 mA, 0 to 10 V, 2 to 10 V, calibrated switchable

Power supply:
24 V DC

Features:
Calibrated signal setting, protective separation, housing width: 6.2 mm

Input:
0 to 20 mA, 4 to 20 mA, 0 to 10 V

Output:
0 to 20 mA, 4 to 20 mA, 0 to 10 V

Power supply:
24 V AC/DC

Features:
Protective separation, housing width: 11.2 mm

Mesuring ranges:
Fixed ranges within 20 Ohm to 1 MOhm, see product line

Output:
0 to 20 mA, 4 to 20 mA, 0 to 5 V, 1 to 5 V, 0 to 10 V, 2 to 10 V

Power supply:
24 V AC/DC

Features:
Protective Separation, housing width: 11.2 mm

Input signal:
Potentiometer 100 Ohm to 100 kOhm

Output signal:
0 to 20 mA, 4 to 20 mA, ±20 mA, 0 to 10 mA, 2 to 10 mA, ±10 mA, 0 to 10 V, 2 to 10 V, ±10 V, 0 to 5 V, 1 to 5 V, ±5V

Power supply:
20 to 253 V AC/DC

Features:
Pluggable screw clamp terminals, zero/span compensation, protective separation, housing width: 12.5 mm

Sensor input:
Pt 100, 4-wire connection

Output:
0 to 20 mA, 4 to 20 mA, 0 to 5 V, 1 to 5 V, 0 to 10 V, 2 to 10 V

Ranges:
-100 to +450 °C  (32 Types)

Power supply:
24 V AC/DC

Features:
Protective Separation, housing width: 11.2 mm

Sensor input:
Pt 100, Pt 1000

Output:
0 to 20 mA, 4 to 20 mA, 0 to 10 V

Ranges: -100 to +600 °C

Power supply:
20 to 253 V AC/DC

Features:
Pluggable screw clamp terminals, sensor diagnostics, protective separation, housing width: 12.5 mm

Sensor input:
Pt 100, 2- or 3-wire connection

Output:
0 to 20 mA, 4 to 20 mA, 0 to 5 V, 1 to 5 V, 0 to 10 V, 2 to 10 V

Ranges:
-100 to +450 °C  (32 types)

Power supply:
24 V AC/DC

Features:
Protective Separation, housing width: 11.2 mm

Sensor input:
Pt 1000, 2- or 3-wire connection

Output:
0 to 20 mA, 4 to 20 mA, 0 to 5 V, 1 to 5 V, 0 to 10 V, 2 to 10 V

Ranges:
-100 to +450 °C  (32 types)

Power supply:
24 V AC/DC

Features:
Protective Separation, housing width: 11.2 mm

Input:
0 to ±60 mV, 0 to ±100 mV, 0 to ±150 mV, 0 to ±250 mV, 0 to ±300 mV, 0 to ±500 mV

Output:
0 to ±20 mA, 0 to ±10 mA, 0 to ±10 V, 0 to ±5 V,  live/dead-zero

Power supply:
20 to 253 V AC/DC

Features:
Pluggable screw clamp terminals, zero/span compensation, protective separation, housing width: 12.5 mm

Input:
0 to ±60 mV, 0 to ±100 mV, 0 to ±150 mV, 0 to ±250 mV, 0 to ±300 mV, 0 to ±500 mV

Output:
0 to ±20 mA, 0 to ±10 mA, 0 to ±10 V, 0 to ±5 V,  live/dead-zero

Power supply:
24 V DC

Features:
signal setting with DIP switches, zero/span compensation, protective separation, housing width: 6.2 mm

Input:
0 to ±60 mV, 0 to ±100 mV, 0 to ±150 mV, 0 to ±300 mV

Output:
0 to 10 V, 2 to 10 V, 0 to 5 V, 1 to 5 V, 0 to 20 mA, 4 to 20 mA

Power supply:
24 V AC/DC

Features:
Protective separation, housing width: 11.2 mm

Sensor Input:
Resistors: Pt 100, Pt 200, Pt 500, Pt 1000, Ni 100, Ni 200, Ni 500, Ni 1000;
Thermocouple: B, E, J, K, L, N, R, S, T, U, W5Re_W26Re, W3Re_W25Re;
KTY, resistor, mV and potentiometer measuring

Output:
0 to 20 mA, 4 to 20 mA, 0 to 10 mA, 2 to 10 mA
0 to 5 V, 0 to 10 V, 1 to 5 V, 2 to 10 V

Measurement Ranges:
-270 to +2315 °C, according to sensor type

Power Supply:
24 V DC

Features:
Protective Separation, Housing width: 6.2 mm

Sensor Input:
Pt 100, Pt 200, Pt 500, Pt 1000, Pt 2000, JPt 50, JPt 100

Output:
0 to 20 mA, 4 to 20 mA, 0 to 5 V, 0 to 10 V

Measurement Ranges:
-200 to +850 °C, according to sensor type

Power Supply:
24 V DC

Features:
Protective Separation, Housing width: 6.2 mm

Sensor Input:
Ni 100, Ni 200, Ni 500, Ni 1000, acc. DIN 43760 (TK6180)
Ni 120 (TK6720), Ni 1000 (TK5000), Ni 1000 (TK6370)

Output:
0 to 20 mA, 4 to 20 mA, 0 to 5 V, 0 to 10 V

Measurement Ranges:
-50 to +250 °C, according to sensor type

Power Supply:
24 V DC

Features:
Protective Separation, Housing width: 6.2 mm

Sensor Input:
Measuring input for all KTY temperature sensors

Output:
0 to 20 mA, 4 to 20 mA, 0 to 5 V, 0 to 10 V

Measurement Ranges:
-50 to +300 °C, according to sensor type

Power Supply:
24 V DC

Features:
Protective Separation, Housing width: 6.2 mm

Sensor Input:
Thermocouple Type A, B, C, D, E, J, K, L, N, R, S, T, U

Output:
0 to 20 mA, 4 to 20 mA, 0 to 5 V, 0 to 10 V

Measurement Ranges:
-200 to +2500 °C, according to type of thermocouple

Power Supply:
24 V DC

Features:
Protective Separation, Housing width: 6.2 mm

Europe card for up to 4 Analog Embedded modules

Module configuration:
with solder jumpers at the europa card

Connector:
Type F according to DIN 41612

Front construction:
128.7 mm x 20.0 mm (3HE x 4TE)

Power terminal for installations with In-Rail-Bus system for standard applications with 4.5 A output current.

Power terminal for installations with In-Rail-Bus system with two separate and reverse polarity protected voltage inputs allow a redundant voltage supply and a maximum current of 3 A.

Power terminal for installation of small applications with In-Rail-Bus and up to 6 devices